Flo-Rite-Temp Model 535
Description
Flo-Rite-Temp Model 535 Instantaneous Steam/Water Heater features a 5″ diameter shell and a non-helical straight internal tube bundle with end cap.
Flo-Rite-Temp Model 535 has 35 GPM capacity with 15PSI steam at a 100°F temperature rise.
Flo-Rite-Temp Model 535 features a unique feed forward design which features a differential pressure diaphragm actuated mixing unit integral to a shell and tube heat exchanger.
The Flo-Rite-Temp Model 535 mixing unit manages the water flow through the heat exchanger based upon downstream hot water demand and eliminates the requirement for a modulating steam control valve.
Operating on constant low pressure (2-15PSI) steam, the Flo-Rite-Temp Model 535 mixing unit supplies water to the heat exchanger where it is overheated and then returned to the mixing unit for proportional re-mixing with cold water to a pre-set outlet temperature.
Request a QuoteContact Form
The differential pressure diaphragm within the mixing unit rapidly responds to a change in system demand and significantly reduces the lag times typically associated with feed back/modulating steam control valve systems.
The Flo-Rite-Temp Model 535 mixing unit’s diaphragm actuated design can be described as “failure safe” because in the event of a diaphragm failure the mixing unit will fail with a cold bias and will not allow hot water to exit the heat exchanger.
Capable of controlling outlet temperatures +/-4°F, this principal of operation offers the additional relevant benefit of reducing the waterborne bacterial content of the water during the overheating process. In addition, with no water storage requirement, Flo-Rite-Temp Model 535 water heaters are a sensible selection as a component of a broader system design initiative for Legionella risk reduction.
Accessible “non helical” admiralty brass straight tubes inside the carbon steel shell available mechanical cleaning and visual inspection. Non modulating constant steam pressure ensures condensate drainage and removes the potential for water hammer damage and corrosion. There is no steam control valve to maintain and typically no supplemental condensate return equipment required.
Model 415
Model 415DW
Model 535
Model 535DW
Model 665
Model 665DW
Model 665SS
Model 8120
Model 8120DW
Model 8120SS
Single Wall
Double Wall
Single Wall
Double Wall
Single Wall
Double Wall
Stainless Steel
Single Wall
Double Wall
Stainless Steel
S5640
S5641
S5642
S5643
S5644
S5645
S5646
S5647
S5648
S5649
No storage tank, small footprint, access via a standard doorway and pre-piped packaged solutions reduce installation time, space and expenditure.